No. Compared with the NCP13992 AC option, AB disables the confirmed dead-time fault response, uses standard skip and retries after external OVP and OTP trips. Its current-sense fault and PFC_MODE skip entries also differ. Evaluate it as a proposed change before any BOM substitution.
No. The AC option retries after feedback, CS_FAULT and confirmed dead-time faults. External OVP and OTP trips latch. The internal die-temperature shutdown has its own release threshold and restarts with soft-start after cooling. Check each resonant controller protection event separately.
No. AD shares the external OVP and OTP latch behavior. Its feedback and current-sense response, skip mode, PFC_MODE status during skip, dead-time fault response and dedicated soft-start option differ. Compare those behaviors on the target power supply.
By Freya Lee
NCP13992ACDR2G is an onsemi half-bridge LLC controller in an SOIC-16 outline with quiet skip and dead-time fault auto-recovery. The NCP13992 AC option latches on external overvoltage and overtemperature trips and retries after feedback and current-sense faults. When evaluating LLC controller alternatives, compare the dead-time clamp, protection and restart sequence against the approved suffix and board.
The NCP13992 AC suffix is a factory-configured option set that pairs quiet skip with dead-time fault auto-recovery and latching external OVP/OTP. The option letters select a factory configuration. The ordering table lists the AC marking as NCP13992AC and the device as a lead-free SOIC-16 with pin positions 2 and 13 omitted, supplied on tape and reel. A shared outline or generic family description cannot identify the option built into the device.
*Figure 1: NCP13992 option-specific maximum dead-time clamp limits and confirmed fault responses. Datasheet conditions are VCC = 12 V, with typical values at TJ = 25 °C and min and max values over TJ = −40 °C to +125 °C. | Source: [onsemi NCP13992 datasheet, Rev. 14, electrical characteristics and IC options](https://www.onsemi.com/download/data-sheet/pdf/ncp13992-d.pdf) | Chart: YG GROUP*No. Evaluate NCP13994AADR2G against the pin assignments and option table for that family when comparing LLC controller alternatives. The AA table entries for OVP, OTP and dead-time fault differ from those of NCP13992AC. Use it as a separate design candidate if engineering can check the required behavior.
State the full AC orderable number, SOIC-16 outline with positions 2 and 13 omitted, reel requirement, quantity and required date. Include the approved BOM and any must-match latch, retry, skip and PFC behavior. Request a separate line for proposed alternatives and traceability evidence.
| Behavior in the onsemi option table | NCP13992ACDR2G | NCP13992ABDR2G | NCP13992ADDR2G |
|---|---|---|---|
| Skip mode | Quiet | Standard | Standard |
| PFC_MODE skip status | On | Off | Off |
| Feedback fault | Auto-recovery | Auto-recovery | Latch |
| CS_FAULT option | Auto-recovery | Off | Latch |
| OVP / OTP input responses | Latch / latch | Auto-recovery / auto-recovery | Latch / latch |
| Dead-time fault response | Auto-recovery | Off | Off |
| Dedicated soft-start sequence | On | On | Off |
Table 1: Selected onsemi factory options; compare the full option table before approval | Source: onsemi NCP13992 datasheet, Rev. 14, pp. 11–12 | Compiled by: YG GROUP
Each row describes a specific function. For example, the PFC_MODE row above concerns its status during skip. An off entry for CS_FAULT does not prove that every current limit is disabled. The external OVP/OTP sense pin can latch the AC option. The controller also monitors its die temperature. Once the die cools below the internal shutdown release threshold, the controller starts again with soft-start, as described on page 26. Write the required resonant controller protection behavior by trigger, response and release condition so the test team knows which event it is checking.
The controller uses the half-bridge transition information sensed at VBOOT to adapt dead time. Its maximum dead-time clamp limits how long the logic waits for the expected transition. If the transition is not detected in that interval, the fault behavior depends on the selected option. Rev. 14 lists a typical count of 16 maximum-dead-time events for the AC option to confirm the fault. The AC row then specifies automatic recovery.
The AB and AD rows still list the same ZVS-or-maximum-dead-time control choice, but their separate dead-time fault response is off. The clamp values also differ: 720/800/880 ns minimum/typical/maximum for AC, versus 120/190/295 ns for AB and AD under the datasheet conditions. Consequently a normal switching waveform does not tell you whether a candidate controller will retry after repeated missed transitions. Ask the power team to review the measured switching transition, the reason for the fault and the observed shutdown and restart sequence together. The event count is separate from the switching time limit.
AB does not preserve the AC behavior. In addition to standard skip, its OVP and OTP responses are automatic recovery instead of latching. A system specified to remain off after an external protection trip can therefore act differently. AD preserves those two latch entries, but changes feedback and current-sense fault behavior, PFC_MODE skip status and the dedicated soft-start sequence. Approve AD only after the revised fault and startup behavior passes on the intended supply.
NCP13994AADR2G is a separate family comparison. Its own Rev. 3 option table lists quiet skip, a voltage feedback mode, auto-recovery for OVP and OTP, and dead-time fault response off for AA. Its similar SOIC outline with the same omitted pin positions does not establish electrical equivalence. Compare pin functions, thresholds and the surrounding power-stage and feedback circuits before deciding whether it belongs in an engineering evaluation.
Verifying a BOM change requires baseline waveforms from the approved AC board across the intended input, load, and thermal range. Record which waveforms and outputs represent a pass for startup, brownout, return from skip and normal load steps. Include the PFC enable state, output behavior, gate waveforms and restart sequence. Use the project's approved lab procedures for overload, external OVP/OTP and any loss of soft switching tests. For each case, document whether the board recovers, waits for a condition to clear or needs a reset.
onsemi's 240 W all-in-one PC supply evaluation manual provides one example of a PFC stage working with an NCP13992-based LLC stage. The schematic identifies its own controller configuration, so the board is useful for identifying signals to observe. Its power, efficiency and protection results do not qualify an AC replacement on another converter.
Request a quote for NCP13992ACDR2G from YG GROUP with the approved BOM revision, required quantity and date, reel requirements and any traceability documents. List the must-match skip, PFC and fault behaviors if you want alternate evaluation. Ask for the exact proposed orderable number and a separate quote line so that an unapproved substitute cannot be mistaken for the AC requirement. For related bench checks, see event-specific fault recovery in an H-bridge and rail sequencing and inrush validation.