No. In DS9083 Rev. 9, the high short-circuit current limit (ILIMH) spans 2 A to 3.8 A at $V_D = 13\text{ V}$ and $V_{IN} = 5\text{ V}$, clamping current until die heating triggers overtemperature shutdown. Size wiring, connectors and PCB traces for the upper clamp limit rather than assuming an exact 2.0 A trip.
Not reliably across tolerance and temperature. DS9083 specifies a maximum input turn-on threshold (VINH) of 3.5 V and characterizes electrical limits at 4.5 V to 5.5 V drive, so use a 5 V logic output or dedicated level-translating buffer plus the recommended I/O protection network.
No. VNLD5300TR-E uses automatic thermal restart, meaning an overheated channel turns back on once junction temperature drops below hysteresis if stays high. Have the MCU read the open-drain pin and pull low after a bounded retry count when latched shutdown is required.
By Alice Chen
VNLD5300TR-E integrates two protected low-side MOSFET channels in an SO-8 package with current limiting and automatic thermal restart. Putting it onto a 12 V body-control or industrial I/O card still hinges on three board checks that catch teams off guard: a 3.5 V maximum logic-high threshold that rejects bare 3.3 V GPIOs, non-latching thermal cycling under hard shorts, and SO-8 copper limits during repetitive relay or solenoid turn-off.
VINH) up to 3.5 V and characterizes main parameters at 4.5 V to 5.5 V input drive.STATUS and enforce a retry cap or latch-off rule if unexpected actuator re-energization is unsafe.INSTATUSINNo. Active drain clamping eliminates an external flyback diode in many designs, but the SO-8 die still dissipates the stored magnetic energy on every turn-off. Verify single-pulse and repetitive switching against DS9083 demagnetization limits on your actual PCB copper at maximum ambient temperature.
Provide the full VNLD5300TR-E tape-and-reel code, build quantity, required delivery date, acceptable date-code window and required automotive/lot traceability documentation, keeping any VNLD5090TR-E comparison line separate until engineering completes load qualification.
According to STMicroelectronics' VNLD5300-E product page and DS9083 Rev. 9 data sheet (Tables 8–12), each channel combines linear current limitation, power limitation and overtemperature shutdown with open-drain STATUS reporting. Those protections save the silicon during a harness short, but they are not a calibrated current-sense cutoff.
During a hard short to battery, VNLD5300TR-E current limiting clamps drain current inside a datasheet window of 2 A to 3.8 A (at $V_D = 13\text{ V}$, $V_{IN} = 5\text{ V}$). Because $V_{DS} \times I_D$ heats the die rapidly, junction temperature climbs to the thermal shutdown threshold, turns the channel off and pulls STATUS low to flag the fault.
| Operating event | Internal VNLD5300TR-E behavior | Required board & firmware decision |
|---|---|---|
| Harness short / overload | Current and power limitation (2 A–3.8 A window) | Size trace width, connector rating and upstream fuse for peak clamp current |
| Sustained fault heating | Overtemperature shutdown + STATUS low, then auto-restart | Poll STATUS, bound retry attempts and command safe latch-off |
| Inductive turn-off | Active drain-to-gate demagnetization clamp | Verify single-pulse and repetitive coil energy at max ambient |
| MCU logic interface | VINH max threshold reaches 3.5 V | Use 5 V logic drive or a qualified level translator ahead of IN1/IN2 |
Table 1: Device protection states versus board-level design responsibilities | Source: STMicroelectronics VNLD5300-E Data Sheet, DS9083 Rev. 9 | Compiled by: YG GROUP
No—a nominal 3.3 V MCU output does not meet worst-case datasheet drive margin. Table 10 of DS9083 Rev. 9 lists an input high-level threshold (VINH) maximum of 3.5 V, and ST specifies on-resistance and protection tables at $V_{IN} = 4.5\text{ V}\text{ to }5.5\text{ V}$. A 3.3 V GPIO—especially after supply tolerance and series current-limiting resistor drop—can pass on a 25 °C lab bench and fail to fully enhance the channel across automotive temperature corners.
Drive IN1 and IN2 from a 5 V buffer/MCU port or an explicit level-shifting stage, size the series protection resistors recommended in ST's application diagram for reverse-battery and transient events, and lock those interface parts on the BOM alongside the driver.
Because automatic thermal restart re-enables conduction as soon as the junction cools below thermal hysteresis, a persistent short will cycle between current limiting, shutdown and re-turn-on indefinitely as long as IN stays high. For door locks, valves, pumps or warning lamps, uncommanded chattering during a fault is rarely acceptable—a system boundary that mirrors our analysis of EV 12 V body-load protection on BTS5030-2EKA and automotive actuator fault-recovery coordination on L9945TR.
Have the host MCU observe STATUS1/STATUS2, count fault assertions within a defined time window and pull IN low to latch off a failed load until diagnostics clear it. Validate dual-channel cross-heating on the real PCB with both channels loaded simultaneously.
Figure 1: Protection state loop and MCU supervision boundary for VNLD5300TR-E based on STMicroelectronics DS9083 Rev. 9, Tables 8–12 | Diagram: YG GROUP
During inductive-load clamping, coil energy plus supply current while demagnetizing is absorbed inside the SO-8 MOSFET die. ST's single-pulse demagnetization curves assume specific starting temperatures and reference copper areas; repetitive PWM or rapid relay cycling on a cramped multi-channel board shrinks thermal headroom fast. Capture drain voltage, coil current, IN and STATUS together on an oscilloscope at maximum enclosure ambient to prove normal turn-off never trips thermal intervention.
When a heavier solenoid or lamp load needs lower on-resistance and higher current capability within ST's VIPower M0-5 family, evaluate STMicroelectronics' VNLD5090-E (VNLD5090TR-E). Even in the same SO-8 outline, higher current limits change short-circuit wire stress, inductive clamp energy and thermal copper requirements, so qualify the complete circuit before updating the AVL.
Build incoming lot and EMS assembly checks around the same electrical boundaries: verify the TR-E tape-and-reel orientation, confirm SO-8 solder-fillet quality and copper-pour continuity on the drain tabs that spread clamping heat, and run an automated functional fixture test that exercises open-load/shorted-load STATUS reporting before conformal coating or potting.
To source through the YG GROUP STMicroelectronics page, submit VNLD5300TR-E, target reel quantities, need-by dates, lot/date-code rules and any approved VNLD5090TR-E evaluation requests via the RFQ form.